Biosafety Cabinet
Laboratory Type A2 Biosafety Cabinet
Class | Class II |
Lighting Type | LED |
Power | 2.5 kW |
Usage/Application | Used in Laboratory |
Material | Mild Steel |
Brand | Nanotech Equipment |
Air Flow Direction | Vertical |
Biosafety Level | BSL 1 |
Voltage | 240 V |
A Type A2 Biosafety Cabinet (often referred to as Class II Type A2 BSC) is a type of Class II Biosafety Cabinet (BSC) designed to provide both operator protection and product protection while handling biological agents, particularly those that might be airborne or potentially hazardous. Type A2 BSCs are commonly used in laboratories where work with moderate-risk biological agents (such as bacteria, viruses, and cell cultures) is performed, and where protection against contamination and exposure is crucial.
Class Third Biosafety Cabinet
Class | Class III |
Lighting Type | LED |
Power | 2.94 kW |
Usage/Application | Used in Laboratory |
Material | Mild Steel |
Brand | Nanotech Equipment |
Air Flow Direction | Horizontal |
Biosafety Level | BSL 1 |
Voltage | 240 V |
A Class III Biosafety Cabinet (also known as a Type III BSC) is the highest level of containment used in laboratories and healthcare settings where highly dangerous biological agents are handled. These cabinets are designed to provide a physically and chemically sterile environment for working with highly infectious agents that pose a significant risk to both the personnel working with the samples and the external environment. Class III Biosafety Cabinets are typically used in laboratories that handle biosafety level 4 (BSL-4) pathogens — the most dangerous pathogens known to science, including the Ebola virus, Lassa fever virus, and other highly infectious diseases that have no vaccines or effective treatments.
Class One Biosafety Cabinet
Class | Class I |
Lighting Type | LED |
Power | 2.5 kW |
Usage/Application | Used in Laboratory |
Material | Stainless Steel |
Brand | Nanotech Equipment |
Air Flow Direction | Vertical |
Biosafety Level | BSL 1 |
Voltage | 240 V |
Class Second Biological Safety Cabinet
Class | Class II |
Lighting Type | LED |
Usage/Application | Used In Laboratory |
Material | Stainless Steel |
Brand | Nanotech Equipment |
Air Flow Direction | Vertical |
Biosafety Level | BSL 1 |
Voltage | 240 V |
Phase | Single Phase |
Frequency | 50 Hz |
Height | 4 Feet |
Noise | 65 dB |
Class II Bio safety cabinet is designed to protect the operator, Product and environment from microorganisms. The inflow air is taking away from the operator, HEPA filtered laminar down flow to protect the product and the exhaust air is through to environment with HEPA filtration system.
Class II Bio Safety cabinets are classified into 4 types
Class II type A1 (formerly A)
Class II type A2 (formerly A/B3)
Class II type B1
Class II type B2
Class II type A1 (formerly A)
This type Bio safety cabinet is designed to protect the operator and Product from contamination and microorganisms. The inflow air is taking away from the operator. It recirculates 70% of air and exhausts 30% of with HEPA filter. Inflow air velocity 75fpm. Designed for general microbial research with low and moderate-risk agents.
Class II type A2 (formerly A/B3)
This type Bio safety cabinet is designed to protect the operator and Product from contamination and microorganisms. If Plenum or Gasket leaks in Positive Pressure Contaminated Plenum, this cabinet is designed to pull the leaks contaminants by blower. It recirculates 70% of air and exhausts 30% of with HEPA filter. Inflow air velocity 90 5fpm. Designed for general microbial research with low and moderate-risk agents.
Class II type B1
This type Bio safety cabinet is designed to protect the operator and Product from contamination and microorganisms. The inflow air is taking away from the operator. It recirculates 30% of air and exhausts 70% of with HEPA filter. Inflow air velocity 90fpm. Designed for general microbial research with low and moderate-risk agents.
Class II type B2
This type Bio safety cabinet is designed to protect the operator and Product from contamination and microorganisms. The inflow air is taking away from the operator and room air, HEPA filtered laminar down flow to protect the product and the exhaust 100% of air is through to environment with HEPA filtration system. Inflow air velocity 90fpm. Designed for general microbial research with low and moderate-risk agents